Indian marine engineer checking the oil mist detector beside the main engine crankcase in a ship's engine room

Second Engineer Orals: Crankcase Explosions and Oil Mist Detectors – 10 Questions

Crankcase explosions are a favourite topic in the Second Engineer (MEO Class II) oral exam, because the surveyor wants to know that you understand the cause, the safety devices and, above all, what you would do when the oil mist detector alarms at sea. This set covers the questions candidates are asked most often, with short model answers.

How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.

Questions and model answers

Q1. How does a crankcase explosion happen?

It starts with a hot spot inside the crankcase, for example an overheated bearing, a seizing piston or crosshead, or hot gases blowing past the piston rings. Lubricating oil splashing on the hot spot evaporates, and the vapour condenses into a very fine oil mist in the cooler parts of the crankcase. When the concentration of this mist reaches its lower explosive limit and meets the hot spot, it ignites and causes an explosion.

Q2. What is the difference between a primary and a secondary explosion?

The primary explosion is the first ignition of the oil mist. It raises the crankcase pressure and may lift the relief valves or blow off doors. As the hot gases cool and contract, a partial vacuum forms. If air is then drawn in, for example through a damaged door or a relief valve that has not reseated, it mixes with the remaining rich mist and a much more violent secondary explosion can follow. This is why relief valves must close quickly and tightly after relieving.

Q3. Which engines must have crankcase explosion relief valves?

Internal combustion engines with a cylinder diameter of 200 mm or more, or a crankcase volume of 0.6 mÂł or more, must be fitted with crankcase explosion relief valves of a suitable type with sufficient relief area. The number, size and position of the valves are set by the classification society rules (IACS UR M9).

Reference: SOLAS Chapter II-1, Regulation 27; IACS UR M9

Q4. Describe a crankcase explosion relief valve and its main features.

It is a light, spring-loaded non-return valve fitted on the crankcase doors. It opens at a small overpressure to release the explosion pressure, then closes quickly to stop air being drawn back in. A flame arrester (a fine steel gauze or similar) inside the valve cools the escaping gases so that no flame comes out into the engine room, and a deflector or cover directs the discharge away from where people stand.

Q5. How does an oil mist detector work?

In the traditional type, a suction fan draws samples from each crankcase compartment in turn through a measuring tube. A light beam passes through the sample to a photocell, and the reduction in light (opacity) shows the mist density. The detector compares each compartment with the others and with a reference, and alarms on high density or on a large difference between compartments, which helps locate the hot spot. Many newer engines use detectors mounted directly on each compartment that measure scattered light, so there are no long sampling pipes and the response is faster.

Q6. The oil mist detector alarms while you are on watch at sea. What do you do?
  • Inform the bridge and the Chief Engineer, and ask for permission to reduce speed. The engine may also slow down automatically.
  • Reduce engine speed to cut the heat generated at the hot spot. Keep everyone away from the crankcase doors and relief valves.
  • Check the detector readings to find which unit is affected, and look at bearing temperatures, lube oil pressure and temperature, and cooling water temperatures.
  • Stop the engine as soon as the bridge says it is safe to do so, and keep the lubricating oil pump running so oil keeps cooling the hot spot.
  • Do not open the crankcase until it has cooled down for the time given in the engine maker’s instructions, to avoid letting air in on a hot, mist-filled crankcase.
  • Keep fire-fighting equipment ready. Once cool, open up under the safety procedure, find and repair the cause, and check the detector before restarting.
Q7. Why must you not open the crankcase doors immediately after stopping?

The crankcase may still hold a dense oil mist and a hot spot. Opening the door lets fresh air in, which can bring the mixture into the explosive range and cause an explosion directly at the person opening the door. The engine must be left to cool for the period the maker recommends before any door is opened.

Q8. Which engines must have an oil mist detector?

Under classification society rules, oil mist detection (or an approved alternative such as bearing temperature monitoring) is required for slow-speed engines of 2,250 kW and above or with a cylinder bore of more than 300 mm, and for medium- and high-speed engines of the same power or bore. The detector type must be approved to IACS UR M67. Check your class society’s current rules for the exact requirements.

Reference: IACS UR M10 and M67; classification society rules

Q9. How do you test an oil mist detector on board?

Follow the maker’s test routine. This usually includes the built-in self-test, a zero or reference check, a functional test using the maker’s test device or test smoke so that the alarm and slowdown signal actually operate, and checks of sampling pipes, filters and lenses for blockage and dirt. Record the test in the planned maintenance system.

Q10. How can crankcase explosions be prevented?

Keep bearing clearances and lube oil quality within limits; maintain the lube oil purifier, filters and coolers; monitor bearing and lube oil temperatures; keep piston rings and the piston rod stuffing box (on crosshead engines) in good condition to prevent blow-by; keep the oil mist detector and relief valves tested and in good order; and investigate any rise in bearing temperature or change in mist readings early.

Quick self-test

Choose your answer, then tap “Show answer” to check.

1. The more violent crankcase explosion is usually: (a) the primary explosion (b) the secondary explosion (c) both are equal (d) the scavenge fire

Answer: (b) The secondary explosion, after air is drawn into the rich mist.

2. SOLAS requires crankcase relief valves on engines with a cylinder diameter of at least: (a) 150 mm (b) 200 mm (c) 250 mm (d) 300 mm

Answer: (b) 200 mm, or a crankcase volume of 0.6 mÂł or more (SOLAS II-1/27).

3. The flame arrester in a relief valve is there to: (a) stop oil leaking (b) cool the escaping gases so no flame enters the engine room (c) measure crankcase pressure (d) let air into the crankcase

Answer: (b) It cools the escaping gases so no flame comes out.

4. After an oil mist alarm and engine stop, the lube oil pump should be: (a) stopped at once (b) kept running (c) switched to the standby filter only (d) drained

Answer: (b) Kept running, so oil keeps cooling the hot spot.

5. A traditional oil mist detector measures mist density by: (a) temperature (b) pressure (c) light obscuration (opacity) (d) humidity

Answer: (c) The reduction of a light beam passing through the sample.

Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. Always follow your engine maker’s instructions and your company’s procedures, and check the current SOLAS, IACS and classification society requirements and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.

Looking for a job at sea? Find the latest maritime vacancies and apply to companies of your choice on WhatsApp with WhatsMate.

This article was prepared with the help of Internet Search and AI assistance tools.