Second Engineer Orals: Air Compressors and Starting Air System – 11 Questions
The air compressor and starting air system come up often in the Second Engineer (MEO Class II) oral exam. Surveyors want to know the rules for compressors and receivers, why compressors are multi-stage, which safety devices protect the system and how a starting air line explosion happens. This set covers the questions candidates are asked most often, with short model answers and the rule behind each one where there is one.
How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.
Questions and model answers
Q1. What do the rules require for starting air compressors and air receivers on a ship whose main engine is started by air?
Two or more air compressors must be fitted, with the capacity shared roughly equally, and at least one must be driven independently of the main propulsion unit with not less than 50% of the total capacity. Together they must be able to charge the receivers from atmospheric pressure within one hour. At least two air receivers of about equal capacity, usable independently, must be fitted. Their total capacity must give, without recharging, not less than 12 consecutive starts alternately ahead and astern for each reversible main engine, or not less than 6 starts for each non-reversible engine. It must also be possible to produce the first charge of air on board without outside help, for example with a hand-started or emergency-powered compressor.
Reference: IACS Unified Requirement M61; your ship’s classification society rules
Q2. Why are starting air compressors built with two or more stages and intercooling?
Compressing air to starting air pressure in one stage would give a very high discharge temperature. That would break down the cylinder lubricating oil, form carbon deposits and create a fire and explosion risk. By compressing in stages and cooling the air between them, each stage works at a lower pressure ratio. This keeps temperatures down, brings compression closer to isothermal so less work is needed, improves volumetric efficiency, and lets moisture condense in the coolers where it can be drained off.
Q3. Name the safety devices and alarms on a two-stage air compressor.
A relief valve after each stage, so a stuck valve or blocked line cannot over-pressurise a stage; a relief valve or bursting disc on the cooling water side of the coolers, so a burst cooler tube cannot over-pressurise the water jacket; high air discharge temperature alarm or trip (a fusible plug on some older designs); low lubricating oil pressure trip; cooling water flow or high temperature alarm; drain valves (manual or automatic) after the coolers; a non-return valve on the discharge line; and unloaders for starting off-load. The exact set and settings are as per the maker’s manual and class approval.
Reference: classification society rules; compressor maker’s instructions
Q4. What is bumping clearance? What happens if it is too large or too small, and how do you check it?
Bumping clearance is the small gap between the top of the piston at top dead centre and the cylinder head or valve plate. If it is too large, more compressed air stays trapped at the end of each stroke and re-expands on the suction stroke, so less fresh air is drawn in and volumetric efficiency and output fall. If it is too small, the piston may strike the head or valves, especially as bearings wear. It is checked by placing a soft lead wire on the piston crown through a valve pocket, turning the compressor over by hand past TDC, and measuring the flattened wire. It is corrected with shims or gaskets of the right thickness as per the maker’s figures.
Q5. What is the purpose of the unloader on an air compressor?
The unloader lets the compressor start and stop without compressing air, usually by holding the suction valves open or opening the stage drains. This reduces the starting load on the motor, avoids high starting current and lets the machine reach full speed and oil pressure before loading. On automatic compressors it also blows down condensate from the coolers and separators at start and stop. A faulty unloader can cause the compressor to run but not build pressure, or to start against full load.
Q6. The compressor is taking much longer than normal to fill the receiver. What could be the causes?
Leaking or broken suction or delivery valves (check the interstage pressure: a high or low reading points to the stage at fault); worn piston rings or liner; excessive bumping clearance; choked suction filter; unloader stuck open or drain valve leaking; relief valve leaking or lifting early; poor cooling giving hot, less dense air; and leaks in the air lines or receiver fittings. Also check the motor speed and belt drive where fitted. Compare charging time and interstage pressure against the trend recorded in the planned maintenance records.
Q7. What mountings are fitted on a starting air receiver, and why must it be drained regularly?
Typical mountings: air inlet valve and main outlet (starting air) valve, an outlet for auxiliary services, pressure gauge, relief (safety) valve, drain valve at the lowest point, a fusible plug where required (to release pressure if the receiver is exposed to fire while isolated from its relief valve), and a manhole for internal inspection.
Air from the compressor carries water and some lubricating oil. If not drained, water causes internal corrosion and can be carried into the starting valves, and oil collects in the receiver and pipes, where it can feed a starting air line fire or explosion. Drain the receivers regularly, and always before manoeuvring, as per your company’s procedures.
Reference: classification society rules for pressure vessels; your company’s SMS procedures
Q8. How does a starting air line explosion happen?
Three things come together: fuel (a film of lubricating oil carried over from the compressor and deposited in the pipes), oxygen (the compressed air itself), and a source of ignition. The usual ignition source is a starting air valve that is leaking or sticking open, so hot combustion gas from the cylinder blows back into the branch pipe and manifold. When starting air is then admitted, the oil film can ignite and the flame and pressure wave run through the pipework. Blanked-off manifold drains, poor draining of receivers and lines, and poor maintenance of the starting valves make it more likely.
Q9. What devices protect the starting air system against explosions?
An isolating non-return valve (or equivalent, normally part of the automatic main starting valve) at the starting air supply connection to each engine, so the manifold is not open to the receiver except while starting. On direct-reversing engines with a starting air manifold, a bursting disc or flame arrester in way of the starting valve of each cylinder; on non-reversing and auxiliary engines, a bursting disc or flame arrester at the supply inlet to the starting air manifold. These devices may be omitted on engines with a bore not exceeding 230 mm. A relief valve may also be fitted on the manifold. Drains at the low points of the manifold must be kept working.
Reference: IACS unified requirements and classification society rules on starting arrangements; engine maker’s instructions
Q10. During manoeuvring you find one starting air branch pipe very hot. What does it mean and what do you do?
A hot branch pipe means the starting air valve on that cylinder is leaking or sticking, letting hot gas blow back into the line, which is the first step towards an air line explosion. Inform the bridge and the Chief Engineer at once. When it is safe and the bridge agrees, stop the engine, shut the main starting air valve and vent the system, and change or overhaul the faulty starting valve. If that cannot be done immediately, follow the maker’s instructions for blanking off that cylinder’s starting valve and check that the engine can still start reliably from all positions. If a bursting disc has blown, replace it only after fixing the valve that caused it. Record the event and check the other starting valves.
Reference: engine maker’s instructions; your company’s SMS procedures
Q11. What is starting air overlap, and why is it needed?
On each cylinder the starting air valve opens at about top dead centre and closes before the exhaust opens, so the air pushes the piston down on the power stroke without being wasted. Overlap means that the opening periods of consecutive cylinders, in firing order, overlap each other. Because of this, at any crank position at least one cylinder is in its starting period, so the engine can be started from any position, ahead or astern. This is why a reversible two-stroke engine needs enough cylinders; with too few there would be dead positions where it cannot start on air. The exact timing figures are given in the engine maker’s manual.
Quick self-test
Choose your answer, then tap “Show answer” to check.
1. For a reversible main engine, the starting air receivers must give without recharging at least: (a) 6 starts (b) 8 starts (c) 12 consecutive starts alternately ahead and astern (d) 20 starts
Answer: (c) 12 consecutive starts alternately ahead and astern; 6 for a non-reversible engine (IACS UR M61).
2. The air compressors together must charge the receivers from atmospheric pressure within: (a) 15 minutes (b) 30 minutes (c) one hour (d) two hours
Answer: (c) One hour, with at least one compressor independent of the main propulsion unit.
3. Too large a bumping clearance mainly causes: (a) piston striking the head (b) lower volumetric efficiency (c) higher motor current (d) water in the receiver
Answer: (b) Trapped air re-expands on the suction stroke, so less fresh air is drawn in.
4. The most common ignition source in a starting air line explosion is: (a) static electricity (b) a leaking or sticking cylinder starting air valve (c) an overheated compressor motor (d) a hot exhaust manifold
Answer: (b) Hot gas blowing back past a faulty starting valve ignites oil deposits in the line.
5. Flame arresters or bursting discs at each cylinder starting valve may be omitted for engines with a bore not exceeding: (a) 150 mm (b) 230 mm (c) 300 mm (d) 400 mm
Answer: (b) 230 mm, under IACS and class rules on starting arrangements.
Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. Please check the current IACS unified requirements, your ship’s classification society rules, the engine and compressor makers’ manuals and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.
This article was prepared with the help of Internet Search and AI assistance tools.