Fuel injection and timing on the two-stroke main engine is a core topic in the Second Engineer (MEO Class II) oral exam. The surveyor wants to see that you understand how the fuel pump meters and times the fuel, what happens when timing goes wrong, and how you would check and correct it on board. This set covers questions commonly asked on this topic, with short model answers.
How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.
Questions and model answers
Q1. Explain how a helix-controlled jerk-type fuel pump works.
A cam on the camshaft drives the plunger up and down inside a closely fitted barrel. When the plunger is at the bottom, fuel at supply pressure fills the barrel through the suction and spill ports. As the plunger rises it covers the ports, the fuel is trapped, and pressure rises quickly until the fuel valve opens and injection begins. Injection continues until the helical edge cut on the plunger uncovers the spill port. The high-pressure fuel then escapes back to the suction side, pressure collapses and the fuel valve closes. On this basic pump the start of injection is fixed by the port position, and the end of injection is varied by the helix.
Q2. How is the quantity of fuel injected controlled?
The governor moves the fuel rack (regulating shaft), which turns each plunger in its barrel. Turning the plunger changes the point at which the helix uncovers the spill port, and so changes the effective stroke: the part of the stroke during which fuel is actually delivered. A larger fuel index means a longer effective stroke and more fuel. At the zero or stop position the vertical groove lines up with the spill port so no pressure builds up and no fuel is injected. Some engines (for example older Sulzer RTA types) use suction and spill valves instead of a helix, but the principle of varying the effective stroke is the same.
Q3. What is fuel pump lead, and how do you check the injection timing of a unit?
Fuel pump lead is the lift of the fuel pump plunger, measured from its bottom position, when the engine piston of that unit is at top dead centre. It tells you whether the fuel cam is correctly positioned on the camshaft. To check it, the engine is turned with the turning gear until the unit is at TDC, and the plunger lift is measured with the maker’s lead gauge or dial gauge, then compared with the value on the test-bed or shop-trial sheet. In service, timing is also judged from performance: indicator or electronic pressure readings of compression pressure (Pcomp) and maximum pressure (Pmax) for each unit, compared with the reference values. The detailed procedure and limits must be taken from the engine maker’s instruction book.
Q4. What is Variable Injection Timing (VIT), and why is it fitted?
VIT automatically changes the start of injection with engine load. Without VIT, the start of injection is fixed, so Pmax falls as load is reduced and part-load fuel consumption is higher. With VIT, injection is advanced as load rises above a low-load point, so Pmax reaches its design value at part load (around 85% MCR on many MAN B&W MC engines) and is then held constant up to full load by retarding injection again. Keeping a high Pmax over the upper load range improves thermal efficiency and reduces fuel consumption. Timing is usually not changed at low loads, so it does not keep shifting during manoeuvring. On MAN B&W MC pumps VIT raises or lowers the pump barrel; on Sulzer RTA engines it changes the closing of the suction valve.
Q5. What are the effects of injection that is too early or too late?
Too early: combustion starts while the piston is still rising, so Pmax and the rate of pressure rise increase. This causes rough, knocking running and higher loads on bearings, piston rings and the cylinder cover, and it raises NOx emissions.
Too late: burning continues well down the expansion stroke (after-burning). Pmax falls, exhaust temperature rises, fuel consumption rises, and there is more smoke and fouling of the scavenge ports, exhaust valve and turbocharger. Hot gas on the liner can also damage the lubricating oil film and the piston rings.
Q6. Pmax on one unit is low compared with the others. What could be the causes and how would you correct it?
First compare Pcomp. If Pcomp is also low, the problem is mainly compression: leaking exhaust valve, worn or broken piston rings, worn liner, or low scavenge air pressure. If Pcomp is normal but Pmax is low, look at injection: worn fuel pump plunger and barrel (needing a higher index for the same load), a leaking suction or puncture valve, worn or wrongly set fuel cam, a defective fuel valve or nozzle, or poor fuel ignition quality. After finding and repairing the cause, the individual unit’s Pmax can be adjusted at the pump (for example the VIT index arm or shims on MAN B&W pumps, as described in the maker’s manual), then a new set of readings is taken to confirm the result.
Q7. What is the purpose of the puncture valve on a fuel pump?
On MAN B&W MC engines the puncture valve is an air-operated valve in the fuel pump top cover. When control air acts on its piston, it opens a path from the high-pressure side back to the suction side, so pressure cannot build up and no fuel is injected even though the plunger keeps moving. It is used to stop injection quickly when the shutdown system acts or the engine is stopped, during the air-start sequence, and, on many installations, when leakage is detected from the double-walled high-pressure pipes. A leaking puncture valve reduces the fuel delivered to that unit and shows up as low Pmax and exhaust temperature.
Q8. How does a fuel valve (injector) work, and how do you test it after overhaul?
A spring holds the needle (or spindle) on its seat. When fuel pump pressure acting on the needle overcomes the spring, the needle lifts and fuel is sprayed through the nozzle holes in fine droplets. When the pump spills, pressure drops and the spring snaps the needle shut, giving a sharp end to injection. On the test rig, check: opening pressure against the maker’s value; that the valve is tight with no dribble just below opening pressure; that all nozzle holes spray with a correct, well-atomised pattern and none are blocked; and that the needle closes cleanly. Many large two-stroke fuel valves also circulate preheated fuel when the engine is stopped, so this path must be clear. Opening pressures and limits are always as per the maker’s instructions.
Q9. Why must fuel viscosity at the engine inlet be controlled?
Correct viscosity is needed for good atomisation and penetration of the spray and for proper lubrication and sealing between the pump plunger and barrel. If viscosity is too high, atomisation is poor, combustion is late and incomplete, and injection pressures rise. If it is too low, the fuel leaks past the plunger and fuel valve, delivery falls, and there is a risk of plunger seizure from poor lubricity. HFO is heated by the viscosity-controlled heater to the range the maker gives (MAN B&W guidance is about 10–15 cSt for HFO), and for distillates MAN Energy Solutions advises keeping viscosity above 2 cSt at engine inlet, cooling the fuel if needed. During fuel changeover, temperature must be changed slowly, as per the maker’s limit, to avoid thermal shock and sticking of pump plungers.
Q10. What does SOLAS require for the high-pressure fuel pipes between the pump and the fuel valve?
All external high-pressure fuel delivery lines between the high-pressure fuel pumps and the fuel injectors must be protected by a jacketed (double-walled) piping system that can contain fuel if the inner pipe fails. The system must include a means of collecting leakage and an alarm to warn of a fuel line failure. The purpose is to stop a fine, high-pressure fuel spray reaching hot surfaces such as the exhaust manifold and starting an engine-room fire. On board, the leak detection alarm should be tested and the drain kept clear as per the planned maintenance system.
Reference: SOLAS Chapter II-2, Regulation 4.2.2.5.2; MSC.1/Circ.1321
Q11. How is fuel injected on an electronically controlled engine such as the MAN B&W ME type?
There is no fuel camshaft. A Hydraulic Power Supply unit delivers high-pressure hydraulic oil to a Hydraulic Cylinder Unit (HCU) at each cylinder. On each HCU, an electronically controlled valve (the FIVA valve, or ELFI on some versions) admits hydraulic oil to a fuel oil pressure booster, whose hydraulic piston drives a fuel plunger and raises the fuel to injection pressure. The Engine Control System decides the start, amount and shape of injection for every cylinder, so timing can be optimised at all loads and there is no need for a mechanical VIT linkage, fuel rack or reversing mechanism on the pump. Other designs, such as common-rail engines, keep fuel at high pressure in a rail and use electronically controlled valves to meter it to each injector. Faults are diagnosed through the control system alarms and the maker’s procedures.
Quick self-test
Choose your answer, then tap “Show answer” to check.
1. In a helix-controlled jerk pump, the quantity of fuel is changed by: (a) changing the cam lift (b) rotating the plunger to change the effective stroke (c) changing the fuel valve spring (d) changing the supply pump pressure
Answer: (b) The fuel rack turns the plunger, changing when the helix uncovers the spill port.
2. Fuel pump lead is the plunger lift measured when: (a) the fuel valve opens (b) the unit’s piston is at TDC (c) the exhaust valve opens (d) the engine is at full load
Answer: (b) It is measured with the unit at top dead centre and compared with the shop-trial value.
3. The main purpose of VIT is to: (a) reverse the engine (b) reduce Pmax at all loads (c) keep a high Pmax at part load for better fuel economy (d) stop injection in an emergency
Answer: (c) Advancing injection at part load raises Pmax and lowers fuel consumption.
4. A typical result of late injection is: (a) high Pmax and knocking (b) high exhaust temperature and after-burning (c) lower fuel consumption (d) higher compression pressure
Answer: (b) Fuel burns late in the expansion stroke, raising exhaust temperature.
5. SOLAS requires the external high-pressure fuel pipes to be: (a) painted red (b) jacketed, with leak collection and an alarm (c) made of copper (d) fitted with flexible hoses only
Answer: (b) Jacketed pipes with leakage collection and a failure alarm (SOLAS II-2/4.2.2.5.2).
Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. Always follow your engine maker’s instructions and your company’s procedures, and check the current SOLAS, IACS and classification society requirements and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.