Second Engineer Orals: Fresh Water Generator – 12 Questions
The fresh water generator (FWG) is one of the auxiliary machines a Second Engineer is expected to know inside out. In the Second Engineer (MEO Class II) oral exam, the surveyor usually checks that you understand why it works under vacuum, how to start and stop it, and how you would deal with high salinity, low output and scale. This set covers the questions candidates are asked most often, with short model answers.
How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.
Questions and model answers
Q1. What is a fresh water generator and why does it work under vacuum?
It is a low-pressure evaporator that makes fresh water from sea water by boiling it and condensing the vapour. An ejector keeps the shell under a high vacuum, typically around 90%, so the sea water boils at only about 40–60 °C instead of 100 °C. This lets the plant use waste heat from the main engine jacket cooling water, which is free energy, and the low boiling temperature also greatly reduces hard scale formation on the heating surfaces.
Q2. Name the main parts of a plate-type fresh water generator and explain how it works.
The main parts are the evaporator (heating section), a separator or demister, the condenser, the ejector pump, the combined brine/air ejector, the distillate (fresh water) pump, the salinometer with a dump valve, a flow meter and the chemical dosing unit.
The ejector pump takes sea water from its own sea suction. Part of it cools the condenser, part is used as feed water, and part drives the brine/air ejector, which pulls out air and the leftover brine to keep the vacuum. Feed water enters the evaporator, where hot jacket water on the other side of the plates boils part of it. The vapour passes through the demister, which stops salt water droplets, and is condensed in the condenser. The distillate pump sends the fresh water through the salinometer cell to the storage tank.
Q3. How do you start a fresh water generator?
- Check the ship is far enough from land and clear of polluted water as per company procedures, and that the main engine is running with jacket water at normal temperature.
- Close the vacuum (air) valve and the drain valve; open the sea water suction and overboard valves.
- Start the ejector pump, check its discharge pressure and wait for the vacuum to build up to about 90%, within the time given by the maker.
- Open the feed water valve and switch on the chemical dosing.
- Slowly open the jacket water outlet and then inlet valves, and adjust the bypass valve to get the specified flow. The boiling temperature rises and the vacuum drops a little as evaporation starts.
- When distillate collects, start the distillate pump and switch on the salinometer. Send water to the tank only when the salinity is below the set point. Note the flow meter reading.
Reference: maker’s instruction manual; company procedures
Q4. How do you stop it, and why is the order important?
First shut off the heating by closing the jacket water valves (and adjusting the bypass so the main engine jacket water temperature stays normal). Then stop the distillate pump and the salinometer, close the feed water valve and stop dosing, stop the ejector pump, open the vacuum valve to break the vacuum and close the sea water valves. The heating is shut off first because, without the ejector and sea water flow, the evaporator would keep boiling with no cooling or brine removal, which overheats the plates and causes heavy scale and salt deposits. For a long stop, follow the maker’s lay-up instructions.
Q5. How does the salinometer work?
Salt dissolved in water makes it conduct electricity, so the salinometer measures the electrical conductivity of the distillate with an electrode cell in the pump discharge. The reading is temperature-compensated and shown in ppm. If salinity goes above the set point, an alarm sounds and a solenoid dump valve sends the water back to the generator or to the bilge instead of the tank. The set point is adjustable and given by the maker; on many plants it is about 10 ppm, and modern plate units are designed to produce water of 2 ppm or less. Check the cell and the alarm regularly as per the planned maintenance system.
Q6. The salinity of the produced water is high. What could be the causes?
- A leak in the condenser plates or gaskets, letting sea water into the distillate side.
- Carry-over (priming) of salt water droplets: brine level too high because the ejector is not removing brine properly, too much feed water, or boiling too violently because of too much heat.
- Damaged or dirty demister.
- Faulty salinometer cell or wrong calibration (check before blaming the plant).
- Starting to send water to the tank before the plant has stabilised.
Q7. The output has dropped. What do you check?
Check the vacuum first. Poor vacuum can come from low ejector pump pressure, a worn or choked ejector nozzle, a choked sea water strainer, an air leak at gaskets, valves or the vacuum valve, or high sea water temperature reducing condenser performance. Then check the heating side: low jacket water temperature (for example at low engine load) or too little jacket water flow through the bypass. Finally check for scale or fouling on the evaporator or condenser plates, wrong feed water flow (choked orifice) and the distillate pump itself.
Q8. What scale forms in a fresh water generator, and how do you prevent and remove it?
The main scale-forming salts in sea water are calcium carbonate, magnesium hydroxide and calcium sulphate, and they start depositing at roughly 60 °C, 77 °C and 88 °C respectively. Because a low-pressure FWG boils below about 60 °C, the scale is mostly soft calcium carbonate, which is fairly easy to remove. To prevent scale, keep the boiling temperature and vacuum within the maker’s range, keep the correct feed water flow so the brine does not become too concentrated, and dose the approved scale inhibitor continuously. To remove it, clean the plates with the maker’s recommended acid cleaning chemical or open and clean them mechanically, following the safety precautions for handling acid.
Q9. Can water from the fresh water generator be used for drinking straight away?
No. Distilled water has almost no minerals, tastes flat and is slightly aggressive to pipes, and because it is produced at low temperature it is not sterilised. Before it is used as drinking water it should be treated: passed through a remineralising (rehardening) filter, disinfected (for example by chlorination or UV, as per the ship’s system) and stored in clean, coated potable water tanks. Residual disinfectant and water quality should be checked and recorded as per company procedures.
Reference: MLC 2006 Regulation 3.2; WHO Guide to Ship Sanitation (3rd edition)
Q10. Where should you not run the fresh water generator, and why?
Do not run it in port, in rivers, estuaries or harbours, close to land, or in any area where the sea may be polluted by sewage, oil or industrial waste. Because the water boils at a low temperature, bacteria and viruses may not be killed, and oil or chemicals can be carried over into the fresh water. Run it only at the minimum distance from land set in your company’s procedures, and stop it if the ship passes through oil or other pollution.
Q11. How can a leak in the evaporator heating plates affect the main engine?
The jacket water is at a higher pressure than the evaporator shell, which is under vacuum, so a leaking plate or gasket lets treated jacket water leak into the evaporator and out with the brine. Signs are a falling jacket water expansion tank level, more make-up water being needed and a faster drop in jacket water treatment chemical concentration. Left unchecked, the main engine cooling system loses water and treatment, which can lead to overheating and corrosion. Isolate the FWG, pressure-test the heating section and renew the plates or gaskets as per the maker’s instructions.
Q12. Compare a vacuum evaporator with a reverse osmosis plant.
A vacuum evaporator uses heat (usually free waste heat from jacket water) and produces very low-salinity water that is also suitable as boiler make-up, but its output depends on main engine load. A reverse osmosis plant pushes sea water at high pressure through semi-permeable membranes, so it needs no heat and can run when the main engine is stopped, but it uses more electrical power, needs careful pre-filtration and membrane care, and its product water usually has higher salinity than distillate. Both need post-treatment before the water is used for drinking.
Quick self-test
Choose your answer, then tap “Show answer” to check.
1. A fresh water generator runs under vacuum mainly to: (a) reduce noise (b) lower the boiling point so waste heat can be used (c) increase sea water flow (d) cool the jacket water faster
Answer: (b) Under vacuum the sea water boils at about 40–60 °C, using jacket water waste heat.
2. The salinometer measures salinity by: (a) density (b) electrical conductivity (c) temperature (d) pH
Answer: (b) Dissolved salt raises the electrical conductivity of the water.
3. When stopping the FWG, the first step is usually to: (a) stop the ejector pump (b) open the vacuum valve (c) shut off the jacket water heating (d) close the sea water overboard valve
Answer: (c) Shutting off the heat first stops boiling without cooling and brine removal.
4. The scale found in a low-pressure FWG is mainly: (a) calcium sulphate (b) calcium carbonate (c) magnesium hydroxide (d) silica
Answer: (b) At low boiling temperatures, soft calcium carbonate scale is the main type.
5. A leak in the condenser plates will most likely cause: (a) high salinity of the distillate (b) loss of jacket water (c) higher output (d) lower boiling temperature
Answer: (a) Sea water leaks into the distillate side and raises its salinity.
Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. Always follow your equipment maker’s instructions and your company’s procedures, and check the current MLC, WHO, IACS and classification society requirements and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.
This article was prepared with the help of Internet Search and AI assistance tools.