Purifiers are part of every engine-room watch, so the surveyor in the Second Engineer (MEO Class II) oral exam expects you to explain how they work, how to set them up for the oil in use, and what to do when something goes wrong. This set covers the purifier questions candidates are asked most often, with short model answers.
How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.
Questions and model answers
Q1. What is the difference between a purifier and a clarifier?
A purifier separates two liquids of different density (oil and water) and also removes solids. It has two outlets, one for clean oil and one for water, and uses a water seal and a gravity disc to hold the oil–water interface in the right place. A clarifier removes solids and only small amounts of water from the oil. It has one liquid outlet, no water seal and no gravity disc; instead the water outlet is closed off (by a clarifier disc or blank), and separated water and solids collect at the bowl periphery and leave with the sludge discharge.
Q2. Explain the principle of centrifugal separation. Which factors affect it?
In a settling tank, heavier water and solids sink slowly under gravity. A purifier bowl spins at high speed, so the centrifugal force is thousands of times stronger than gravity and the same separation happens in seconds. The heavier water and solids move outward to the bowl wall, while the lighter oil moves inward to the clean oil outlet. The disc stack divides the oil into thin layers so particles only travel a short distance before they are caught.
From Stokes’ law, the separation speed of a particle increases with its size, with the density difference between the particle and the oil, and with the centrifugal force, and it decreases as the oil viscosity increases. That is why we heat the oil and keep the feed rate low.
Q3. What is a gravity disc, and how do you select the correct one?
The gravity disc (dam ring) sets the position of the oil–water interface inside the bowl. Its inside diameter decides how far out the interface sits. For best separation, the interface should be outside the disc stack but inside the edge of the top disc, so the water seal is not broken.
Select it from the maker’s nomogram or chart using the oil’s density at 15°C, the separation temperature and, for some makers, the throughput. Start with the largest disc that does not break the seal. Check the choice again every time the fuel or its density changes. For conventional purifiers with a gravity disc, the practical maximum fuel density is about 991 kg/m³ at 15°C; denser fuels need a self-adjusting separator system such as one with a water transducer in the clean oil outlet.
Reference: separator maker’s instruction manual and gravity disc nomogram
Q4. What happens if the gravity disc is too large or too small?
Too large (inside diameter too big): the interface moves outward towards the bowl wall. The water seal can break and oil escapes through the water outlet, so you lose fuel and may get an alarm or oily water in the sludge tank.
Too small: the interface moves inward, into the disc stack. Separation efficiency falls and water and solids pass with the clean oil to the service tank.
Q5. Why is the oil heated before the purifier, and to what temperature?
Heating lowers the oil’s viscosity and, because oil density falls faster than water density with temperature, it also increases the density difference between oil and water. Both make separation faster and better. For heavy fuel oil, makers and fuel experts usually recommend a separation temperature of 98°C, kept steady. Lube oil and distillate fuel are separated at the lower temperatures given in the maker’s instructions. A wrong or fluctuating temperature also moves the interface and can cause a seal break.
Q6. What are sealing water, displacement water and operating water?
- Sealing water: fresh water added to a purifier bowl before oil is fed, to form the water seal. Without it, oil would flow straight out through the water outlet.
- Displacement water: water added just before a sludge discharge to push the oil out of the bowl towards the clean oil outlet, so less oil is lost with the sludge.
- Operating (control) water: water supplied to the bowl’s operating system to open and close the sliding bowl bottom for sludge discharge and to keep the bowl closed during separation.
Q7. What are cat fines, and how do you keep them away from the main engine?
Catalytic fines are very hard, tiny particles of aluminium and silicon compounds left in residual fuel from the refinery’s catalytic cracking process. In the engine they cause severe abrasive wear of liners, piston rings and fuel pumps. ISO 8217 allows residual fuel to be delivered with up to 60 mg/kg of aluminium plus silicon, but most engine makers want no more than 10–15 mg/kg at the engine inlet, so the fuel treatment system must remove most of them.
Good practice: drain settling and service tanks regularly; keep the separation temperature steady; run the purifiers continuously with the feed rate matched to engine consumption rather than at full capacity; use the correct gravity disc; keep the bowl clean and in good condition; and keep the fine filter after the purifiers in good order. Take fuel samples before and after the purifier to check how well it is working.
Reference: ISO 8217 (residual fuels); engine maker’s fuel guidelines
Q8. Why is a low feed rate better? How would you set the throughput?
A lower feed rate gives the oil more time in the bowl, so smaller particles and more water have time to reach the bowl wall. Running a purifier at its full rated capacity, with the excess oil overflowing back to the settling tank, gives poorer cleaning. Set the throughput a little above the engine’s actual fuel consumption so the service tank stays full and keeps overflowing slowly, and adjust it when the engine load changes. Some modern systems control the feed pump automatically from engine load.
Q9. The purifier is losing oil through the water outlet (seal break). What are the possible causes?
- Gravity disc too large for the oil density, or wrong disc after a fuel change.
- Not enough sealing water, or sealing water not added before feeding oil.
- Feed rate too high, or oil fed too suddenly at start.
- Separation temperature too high or fluctuating.
- Bowl not closing fully: worn or damaged main seal ring, low operating water pressure, or a faulty operating water valve.
- Back pressure on the clean oil outlet too high, or bowl speed low (slipping friction clutch or belt).
Stop the oil feed, find and correct the cause, then restart following the maker’s starting sequence.
Q10. The purifier starts vibrating heavily. What could be the cause and what do you do?
Common causes are uneven sludge built up in the bowl, a bowl that was not cleaned or was assembled wrongly, parts from another bowl fitted (bowl parts are balanced as a set), damaged disc stack, worn spindle bearings or damaged spindle springs, or a loose foundation.
Stop the feed and stop the motor at once, and keep people away from the separator. Use the brake only if the maker’s instructions allow it. Do not try to dismantle anything until the bowl has completely stopped. Then open up, clean the bowl, check the parts and bearings, and reassemble correctly before restarting.
Q11. What safety precautions do you take when overhauling a purifier?
- Follow the permit-to-work and lock-out procedure: isolate the motor electrically and isolate the oil, steam/heater and water supplies.
- Make sure the bowl has completely stopped before loosening any part (check the revolution indicator or the spindle).
- Let hot parts cool, and drain oil from the bowl and frame.
- Use the maker’s special tools and lifting gear. Check the alignment marks on the lock ring and bowl parts and tighten exactly as instructed.
- Never swap bowl parts between purifiers, because each bowl is balanced as a set.
- Inspect the bowl for corrosion, erosion and cracks, and renew seals and O-rings as per the maker. Record the overhaul in the planned maintenance system.
Q12. What fire protection is required for purifiers handling heated fuel oil?
Purifiers for heated fuel oil are a recognised fire hazard because hot oil can leak or spray onto hot surfaces. On passenger ships of 500 GT and above and cargo ships of 2,000 GT and above, category A machinery spaces of more than 500 m³ must have a fixed water-based (or equivalent) local application fire-fighting system covering, among other areas, purifiers for heated fuel oil, in addition to the main fixed system. Class rules also prefer purifiers to be in a separate purifier room, or if that is not practical, to have shielding, drip trays and good ventilation. On board, keep drip trays and drains clean, report leaks at once and keep the local application system ready for use.
Reference: SOLAS Chapter II-2, Regulation 10.5.6; MSC.1/Circ.1387; classification society rules
Quick self-test
Choose your answer, then tap “Show answer” to check.
1. A clarifier differs from a purifier because it: (a) has two liquid outlets (b) has no gravity disc and no water seal (c) runs at a lower speed (d) cannot remove solids
Answer: (b) A clarifier has one liquid outlet and no water seal or gravity disc.
2. If the gravity disc inside diameter is too large, the most likely result is: (a) water in the clean oil (b) a broken water seal and oil lost through the water outlet (c) higher bowl speed (d) no effect
Answer: (b) The interface moves outward and the seal breaks.
3. The usual recommended separation temperature for heavy fuel oil is: (a) 60°C (b) 75°C (c) 98°C (d) 120°C
Answer: (c) 98°C, kept steady, unless the maker says otherwise.
4. According to Stokes’ law, separation becomes slower when: (a) particle size increases (b) density difference increases (c) oil viscosity increases (d) bowl speed increases
Answer: (c) Higher viscosity slows the particles, which is why oil is heated.
5. ISO 8217 allows residual fuel to be delivered with aluminium plus silicon up to: (a) 15 mg/kg (b) 30 mg/kg (c) 60 mg/kg (d) 100 mg/kg
Answer: (c) 60 mg/kg as delivered; engine makers want about 10–15 mg/kg at the engine inlet.
Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. Always follow your separator maker’s instructions and your company’s procedures, and check the current SOLAS, ISO 8217 and classification society requirements and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.