Second Engineer Orals: Pumps and Pumping Systems – 12 Questions
Pumps are everywhere in the engine room, so the surveyor in the Second Engineer (MEO Class II) oral exam often starts with a simple pump question and then moves on to the bilge system and the fire pumps. You are expected to know how pumps work, why they fail, and what SOLAS and class rules say about bilge and fire pumping. This set covers the questions commonly asked on this topic, with short model answers.
How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.
Questions and model answers
Q1. How are pumps classified, and where is each type used on board?
Pumps are of two main groups. Dynamic (rotodynamic) pumps, mainly centrifugal and axial flow pumps, give energy to the liquid with a rotating impeller; their delivery changes a lot with the discharge pressure. They are used for sea water and fresh water cooling, ballast, fire, general service and cargo pumps on tankers. Positive displacement pumps move a fixed volume per stroke or revolution. They include reciprocating (piston) pumps, gear pumps, screw pumps and vane pumps. They are self-priming and suit viscous liquids and high pressures, so they are used for fuel oil and lube oil transfer and supply, bilge and sludge pumps, stripping pumps and hydraulic systems such as steering gear.
Q2. Why is a centrifugal pump usually started with the discharge valve closed, while a positive displacement pump must never be?
For a normal radial centrifugal pump, the power taken is lowest at zero flow. Starting against a closed discharge valve keeps the starting current of the motor low and avoids water hammer in the line. The valve is then opened slowly once the pump has built up pressure. It must not be left running for long against a closed valve, because the liquid heats up and can vaporise, damaging the pump and seal.
A positive displacement pump keeps pushing the same volume whatever the resistance. If the discharge is closed, the pressure rises until something gives way: the pipe, a joint, the pump casing or the motor. So it is always started with the suction and discharge valves open, and it must have a relief valve.
Q3. Why does a centrifugal pump need priming, and how is it done on board?
An impeller full of air cannot create enough suction to lift water, because air is far lighter than water. The casing and suction line must be full of liquid before the pump can deliver. When the pump is below the liquid level (flooded suction), as with most sea water pumps, it primes itself by gravity. When it must lift liquid, as with bilge and ballast suctions, a priming device removes the air: an attached water ring (liquid ring) vacuum pump, an air ejector, or a central priming system serving several pumps. A foot valve or non-return valve helps keep the suction line full.
Q4. What is cavitation? What are its causes and signs, and how do you prevent it?
Cavitation happens when the pressure at the impeller eye falls below the vapour pressure of the liquid. Vapour bubbles form and then collapse violently as they move into the higher pressure zone, pitting the impeller and casing. In pump terms, the net positive suction head available (NPSHa) has fallen below the NPSH the pump requires (NPSHr).
Causes include a choked suction filter or strainer, a partly closed suction valve, too high a suction lift, a low tank level, high liquid temperature, and running far beyond the design flow. Signs are a rattling noise like gravel in the pump, vibration, fluctuating discharge pressure and motor current, and reduced delivery. Prevent it by keeping suction strainers clean, keeping suction valves fully open, keeping a good level in the tank, avoiding overheated liquid, and throttling on the discharge side, never the suction side.
Q5. A centrifugal pump is running but delivering little or no liquid. What will you check?
- Loss of prime: air leaking into the suction line through a joint, a valve gland or the pump gland, or a priming device not working.
- Suction side: closed or partly closed valve, choked strainer or sea chest grid, low tank level, or too high a suction lift.
- Discharge side: wrong valve line-up, closed valve, or a stuck non-return valve.
- Pump itself: worn wear rings (large clearance lets liquid recirculate from discharge to suction), damaged or clogged impeller, or loose impeller on the shaft.
- Drive: wrong direction of rotation after electrical work, low speed, or a slipping coupling.
Q6. Why does a positive displacement pump have a relief valve, and how is it arranged?
Because the pump keeps delivering a fixed volume, a blocked filter or closed valve on the discharge would make the pressure rise without limit. The relief valve, fitted on the discharge side or built into the pump casing, opens at a set pressure above normal working pressure and returns the liquid to the suction side or to the tank. If it returns to the suction for a long time, the liquid heats up, so the cause of the high pressure must be found quickly. The relief valve setting is checked during maintenance as per the maker’s instructions and must not be raised to “cure” a problem.
Q7. Compare a gland packing with a mechanical seal. Why should a packed gland leak slightly?
A gland packing is a set of soft rings compressed around the shaft sleeve by a gland follower. It must be allowed to drip slightly, because the leaking liquid lubricates and cools the packing. If it is tightened until dry, the packing burns and scores the sleeve. Packing is cheap and can be renewed without stripping the pump, but it needs regular adjustment and wastes some liquid.
A mechanical seal has a rotating face and a stationary face, lapped very flat and held together by a spring, with secondary seals (O-rings or bellows). A thin liquid film between the faces lubricates them and there is almost no visible leakage. It needs no adjustment and suits oils and hazardous liquids, but it is damaged by running dry, by abrasive particles and by misalignment, and changing it usually means opening the pump.
Q8. What happens when two centrifugal pumps run in parallel, and when they run in series?
In parallel, both pumps take suction from the same line and discharge into a common line. At the same head their flows add up, so parallel running is used when more flow is needed, such as two ballast or cooling pumps. Because system resistance rises with flow, the total is usually less than double. The pumps should be similar; a weaker pump may be pushed back to near zero flow and overheat, which is why each has a non-return valve on the discharge.
In series, one pump discharges into the suction of the next. At the same flow their heads add up, so series running is used when higher pressure or a longer lift is needed, as in a booster pump arrangement.
Q9. Describe the bilge pumping arrangement of a cargo ship and the main rules for it.
A cargo ship must have at least two power pumps connected to the main bilge system, and one of them may be driven by the propulsion machinery. Ballast, sanitary or general service pumps of enough capacity can serve as bilge pumps if connected to the bilge system. The main bilge line has branch suctions to each hold and to the machinery space, and direct suctions from the pumps in the engine room. The size of the main bilge pipe comes from a class formula based on the ship’s length, breadth and depth, and each power bilge pump must be able to move water through it at a speed of at least 2 m/s.
Key features: bilge valves in the distribution boxes are screw-down non-return valves, so water cannot flow back from the sea or from one compartment to another; suctions in the machinery space lead from mud boxes, and hold suctions are fitted with strainers (rose boxes); valves are accessible and clearly labelled; and bilge pipes are kept separate from pipes used to fill or empty tanks holding water or oil. Oily bilge water from the engine room goes to the bilge holding tank and is discharged only through the oily water separator under MARPOL Annex I.
Reference: SOLAS Chapter II-1, Regulation 35-1; classification society rules; MARPOL Annex I
Q10. What is the emergency bilge suction in the engine room, and when would you use it?
It is a direct suction from the engine room bilge to the largest available power-driven pump, usually the main sea water cooling (circulating) pump, fitted with a screw-down non-return valve whose spindle is extended so it can be opened from above the floor plates. It is used only when the engine room is flooding faster than the bilge pumps can cope, for example after a pipe burst or hull damage. Because it pumps bilge water directly overboard, it is an emergency measure to save the ship, and its use must be recorded in the Oil Record Book. The valve must be kept free to operate, clearly labelled, and checked regularly under the planned maintenance system. The exact arrangement and pipe size are set by class rules.
Reference: classification society rules; MARPOL Annex I, Regulation 4 (exceptions for the safety of the ship)
Q11. What are the SOLAS requirements for the main fire pumps of a cargo ship of 1,000 GT and above?
- At least two independently driven fire pumps.
- Together (not counting the emergency fire pump) they must deliver at least four-thirds of the quantity each bilge pump must handle under SOLAS II-1/35-1, though for most cargo ships the total need not exceed 180 m³/h.
- Each required fire pump must have a capacity of at least 80% of the total required capacity divided by the number of required pumps, and not less than 25 m³/h.
- With two pumps delivering through adjacent hydrants, the minimum pressure at all hydrants is 0.27 N/mm² for cargo ships of 6,000 GT and above, and 0.25 N/mm² for those below 6,000 GT.
- Relief valves are needed if the pumps can develop a pressure above the design pressure of the fire main, hydrants and hoses.
- An isolating valve outside the machinery space allows the part of the fire main inside the space with the main fire pumps to be isolated, so the emergency fire pump can still supply the rest of the ship.
Reference: SOLAS Chapter II-2, Regulation 10.2
Q12. When is an emergency fire pump required, and what are its main requirements?
In a cargo ship, if a fire in any one compartment could put all the main fire pumps out of action, a fixed, independently driven emergency fire pump must be provided. It, its sea suction and its power source must be outside the space containing the main fire pumps. Its capacity must be at least 40% of the total required capacity of the main fire pumps, and not less than 25 m³/h for cargo ships of 2,000 GT and above (15 m³/h below 2,000 GT). At that delivery, the pressure at the hydrants must be not less than the minimum required by SOLAS Chapter II-2.
If diesel driven, the engine must start readily from cold down to 0°C by hand cranking (or another approved means), and its service tank must hold enough fuel for at least 3 hours at full load, with a reserve outside the main machinery space for a further 15 hours. On board, it is run and tested regularly, including checking the suction lift and the pressure at the highest hydrant, as per the company’s procedures and the maker’s instructions.
Reference: SOLAS Chapter II-2, Regulation 10.2; FSS Code Chapter 12
Quick self-test
Choose your answer, then tap “Show answer” to check.
1. Which pump must never be started against a closed discharge valve? (a) a radial centrifugal pump (b) a screw pump (c) an axial flow pump at low speed (d) a pump with a flooded suction
Answer: (b) A screw pump is a positive displacement pump, so the pressure would rise until something fails.
2. Cavitation occurs when: (a) NPSH available is more than NPSH required (b) NPSH available falls below NPSH required (c) the discharge valve is fully open (d) the gland drips slightly
Answer: (b) The suction pressure falls below the vapour pressure and bubbles form and collapse.
3. Two similar centrifugal pumps running in parallel mainly increase: (a) head (b) flow (c) suction lift (d) NPSH required only
Answer: (b) In parallel the flows add up at the same head; in series the heads add up.
4. The minimum pressure at the hydrants of a cargo ship of 6,000 GT and above is: (a) 0.25 N/mm² (b) 0.27 N/mm² (c) 0.30 N/mm² (d) 0.40 N/mm²
Answer: (b) 0.27 N/mm² (SOLAS II-2/10.2); 0.25 N/mm² applies below 6,000 GT.
5. The capacity of the emergency fire pump must be at least: (a) 25% of the main fire pumps’ total (b) 40% of the total, and not less than 25 m³/h for cargo ships of 2,000 GT and above (c) 80% of one main fire pump (d) equal to one main fire pump
Answer: (b) FSS Code Chapter 12 sets 40% of the total required capacity, with a minimum of 25 m³/h (15 m³/h for cargo ships below 2,000 GT).
Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. Always follow your equipment maker’s instructions and your company’s procedures, and check the current SOLAS, FSS Code, MARPOL and classification society requirements and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.