Second Engineer Orals: Sewage Treatment Plant and MARPOL Annex IV – 12 Questions
Sewage and MARPOL Annex IV come up often in the Second Engineer (MEO Class II) oral exam. The surveyor usually checks two things: that you know the rules on equipment and discharge, and that you can explain how the sewage treatment plant on your ship works and what you do when it gives trouble. This set covers the questions candidates are asked most often, with short model answers.
How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.
Questions and model answers
Q1. What is “sewage” under MARPOL Annex IV? Is grey water included?
Sewage means drainage and other wastes from any form of toilets and urinals; drainage from medical premises (dispensary, sick bay) through wash basins, wash tubs and scuppers in those premises; drainage from spaces carrying living animals; and any other waste water when it is mixed with these drains. Grey water from showers, laundry and galley on its own is not sewage under Annex IV, but it becomes sewage if it is mixed with sewage drains. Some ports and coastal states have their own grey water rules.
Reference: MARPOL Annex IV, Regulation 1
Q2. Which ships must comply with Annex IV, and what certificate do they carry?
Annex IV applies to ships on international voyages of 400 gross tonnage and above, and to ships below 400 GT that are certified to carry more than 15 persons. These ships carry an International Sewage Pollution Prevention (ISPP) Certificate, issued after an initial survey and renewed after a renewal survey. It is valid for not more than five years. Unlike the IOPP Certificate, it has no annual or intermediate survey endorsements. The certificate states which system the ship has: a treatment plant, a comminuting and disinfecting system, or a holding tank. In India, these rules are applied through the Merchant Shipping (Prevention of Pollution by Sewage from Ships) Rules, 2010.
Reference: MARPOL Annex IV, Regulations 2, 4 and 5
Q3. What sewage equipment must be fitted on a ship under Annex IV?
The ship must have one of the following: an approved sewage treatment plant; or an approved sewage comminuting and disinfecting system, with facilities to store sewage temporarily when the ship is less than 3 nautical miles from the nearest land; or a holding tank of a capacity approved by the Administration, with a visual means of showing how much it contains. In addition, every ship under Annex IV must have a pipeline to a standard shore discharge connection, so that sewage can be pumped to a port reception facility. This applies whatever system is fitted.
Reference: MARPOL Annex IV, Regulations 9 and 10
Q4. When may sewage be discharged into the sea outside a special area?
- Comminuted and disinfected sewage, using an approved system: more than 3 nautical miles from the nearest land.
- Sewage that is not comminuted or disinfected: more than 12 nautical miles from the nearest land, with the ship en route at not less than 4 knots. Sewage from holding tanks must not be discharged all at once, but at a moderate rate approved by the Administration.
- Effluent from an approved sewage treatment plant that is in operation: allowed at any distance, provided the test results are on the ISPP Certificate and the effluent does not produce visible floating solids or discolour the surrounding water.
These rules do not apply when the discharge is needed to secure the safety of the ship and people on board or to save life at sea, or when it results from damage to the ship or its equipment and all reasonable precautions were taken. Local and port rules may be stricter.
Reference: MARPOL Annex IV, Regulations 3 and 11
Q5. Which is the special area under Annex IV, and which ships does it affect?
The Baltic Sea is currently the only Annex IV special area, and its rules apply to passenger ships (ships carrying more than 12 passengers). Inside it, a passenger ship may not discharge sewage unless it has an approved treatment plant meeting the stricter MEPC.227(64) standard, which includes nitrogen and phosphorus removal. Otherwise the sewage must be kept on board and landed ashore. The requirement took effect on 1 June 2019 for new passenger ships, 1 June 2021 for most existing passenger ships, and 1 June 2023 for certain existing passenger ships trading directly to ports in the far east of the Baltic. Cargo ships in the Baltic follow the normal Regulation 11 rules.
Reference: MARPOL Annex IV, Regulations 1 and 11.3; resolution MEPC.275(69)
Q6. Describe the standard sewage discharge connection.
It is a flat-faced steel flange with an outside diameter of 210 mm and a bolt circle diameter of 170 mm, with 4 slotted holes of 18 mm diameter and a thickness of 16 mm, fastened with 4 bolts of 16 mm diameter. It accepts pipes of up to 100 mm internal diameter, and with a suitable gasket it must be good for a service pressure of 600 kPa. For ships with a moulded depth of 5 m or less, the inner diameter may be 38 mm. A useful way to remember it: the Annex I (oily waste) flange is bigger, at 215 mm outside diameter with 6 bolts.
Reference: MARPOL Annex IV, Regulation 10
Q7. Explain how a biological (extended aeration) sewage treatment plant works.
Raw sewage enters the aeration chamber, where a blower supplies air through diffusers. Aerobic bacteria use this oxygen to break down the organic matter into carbon dioxide, water and more bacterial sludge. The mixture then flows into the settling (clarification) chamber, where the sludge settles in calm conditions. Settled sludge is returned to the aeration chamber, usually by an air-lift, to keep the bacteria population up, and excess sludge is removed from time to time. The clear liquid passes to the disinfection chamber, where it is treated, usually with chlorine, to kill harmful bacteria. On many newer plants a dechlorination step follows. The discharge pump, controlled by level switches, then pumps the treated effluent overboard or to a holding tank.
Q8. What effluent standards must a sewage treatment plant meet?
For plants installed on or after 1 January 2016, the type-approval standards in resolution MEPC.227(64) are: thermotolerant coliforms not more than 100 per 100 ml (geometric mean); total suspended solids 35 mg/l (with an adjustment for dilution and flushing water); BOD5 25 mg/l; COD 125 mg/l; pH between 6 and 8.5; and total residual chlorine below 0.5 mg/l. Plants installed between 1 January 2010 and 1 January 2016 are approved to MEPC.159(55), and older plants to MEPC.2(VI). The additional nitrogen and phosphorus limits in MEPC.227(64) apply only to passenger ships discharging in a special area.
Reference: Resolution MEPC.227(64), as amended by MEPC.284(70)
Q9. What routine checks and maintenance do you carry out on a sewage treatment plant?
- Check that the blower is running and air is bubbling evenly in the aeration chamber; clean or renew blocked diffusers.
- Check that the sludge return air-lift is working, and remove excess sludge when the settling test or the maker’s limit shows it is needed.
- Keep enough disinfectant (and dechlorination chemical, if fitted) in stock and check the dosing unit.
- Test the level switches, high-level alarm and discharge pump; check the effluent for clarity and smell.
- Clean filters and screens, and check vents are clear so gases do not build up.
- Remind crew not to flush strong cleaning chemicals, oil, paints or large amounts of disinfectant into toilets, as these can kill the bacteria.
Follow the maker’s manual and record the work in the planned maintenance system.
Q10. The effluent from the treatment plant is cloudy and smells bad. What could be wrong and what do you do?
Common causes are: loss of air (blower stopped, belt broken, diffusers or air lines blocked), so the bacteria die and the plant turns anaerobic and septic; harmful chemicals flushed into the system; overloading with more people than the plant is designed for; too much sludge carrying over from the settling chamber; or no disinfectant in the dosing unit. Restore the air supply first, then desludge if needed, stop the source of chemicals, top up the disinfectant, and give the bacteria time to recover, following the maker’s restart procedure. Until the effluent is good, do not discharge it as treated effluent: hold it on board or discharge only where Regulation 11 allows untreated sewage, and inform the Chief Engineer.
Q11. What are the hazards of sewage systems, and what precautions do you take before entering a sewage tank?
Rotting sewage gives off hydrogen sulphide, which is very toxic and can deaden your sense of smell, and methane, which is flammable. The tank atmosphere can also be short of oxygen, and the contents carry harmful bacteria. A sewage tank is an enclosed space, so entry must follow the company’s enclosed space entry procedure: a risk assessment and entry permit, isolating and draining the tank, thorough ventilation, testing the atmosphere for oxygen, hydrogen sulphide and flammable gas before entry and continuously during the work, a standby person at the entrance with communication and rescue equipment ready, and suitable PPE and good personal hygiene afterwards.
Reference: SOLAS Chapter XI-1, Regulation 7; resolution A.1050(27) (enclosed space entry)
Q12. What will a port State control officer typically check under Annex IV?
The officer will check that a valid ISPP Certificate is on board and that the system described on it matches what is actually fitted. They may ask to see the treatment plant running, check that disinfectant and other chemicals recommended by the maker are available in enough quantity, look at the holding tank level indication, the standard discharge connection and pipeline, and ask the engineers how the plant is operated and when sewage may be discharged. A plant that is not working, or crew who do not know how to run it, can lead to a deficiency.
Reference: MARPOL Annex IV, Regulation 13 (port State control on operational requirements)
Quick self-test
Choose your answer, then tap “Show answer” to check.
1. Untreated sewage (not comminuted or disinfected) may be discharged at more than: (a) 3 nm (b) 4 nm (c) 12 nm (d) 25 nm from the nearest land, en route at not less than 4 knots
Answer: (c) More than 12 nautical miles, at a moderate rate (Regulation 11).
2. Annex IV applies to ships on international voyages of 400 GT and above, or certified to carry more than: (a) 12 persons (b) 15 persons (c) 25 persons (d) 50 persons
Answer: (b) More than 15 persons (Regulation 2).
3. The outside diameter of the standard sewage discharge flange is: (a) 170 mm (b) 183 mm (c) 210 mm (d) 215 mm
Answer: (c) 210 mm; 170 mm is its bolt circle, and 215 mm is the Annex I oily waste flange.
4. In an extended aeration treatment plant, the organic matter is broken down mainly by: (a) chlorine (b) anaerobic bacteria (c) aerobic bacteria (d) heating
Answer: (c) Aerobic bacteria, kept alive by the air from the blower.
5. The only special area under MARPOL Annex IV at present is: (a) the Mediterranean Sea (b) the Baltic Sea (c) the North Sea (d) the Red Sea
Answer: (b) The Baltic Sea, for passenger ships.
Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. Always follow your equipment maker’s instructions and your company’s procedures, and check the current MARPOL Annex IV text, IMO guidelines, flag State requirements and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.
This article was prepared with the help of Internet Search and AI assistance tools.