Second Engineer Orals: Oily Water Separator and MARPOL Annex I – 12 Questions
Oily water separators and MARPOL Annex I come up in almost every Second Engineer (MEO Class II) oral exam. The surveyor wants to see that you know the discharge rules, understand how the separator and the 15 ppm bilge alarm work, can deal with a fault on watch, and keep an honest Oil Record Book. This set covers the questions candidates are asked most often, with short model answers.
How to use this set: read each question, answer it aloud as you would in front of the surveyor, then open the model answer to check yourself.
Questions and model answers
Q1. Which ships must be fitted with oil filtering equipment, and what type?
Every ship of 400 GT and above but less than 10,000 GT must have approved oil filtering equipment (a 15 ppm bilge separator) that gives an effluent of not more than 15 ppm. Every ship of 10,000 GT and above must have the same equipment plus a 15 ppm bilge alarm and an automatic stopping device that stops the overboard discharge when the oil content goes above 15 ppm. Ships below 400 GT must, as far as practicable, keep oily mixtures on board for discharge ashore, or meet the discharge conditions for small ships.
Reference: MARPOL Annex I, Regulation 14
Q2. When may a ship of 400 GT and above pump machinery space bilge water overboard outside special areas?
Only when all these conditions are met: the ship is proceeding en route; the oily mixture is processed through oil filtering equipment meeting Regulation 14; the oil content of the effluent without dilution does not exceed 15 ppm; and, on an oil tanker, the bilge water does not come from cargo pump room bilges and is not mixed with oil cargo residues. If any condition cannot be met, the oily water must be kept on board and landed to a reception facility.
Reference: MARPOL Annex I, Regulation 15.2
Q3. Name the Annex I special areas. What changes inside them?
The Annex I special areas are the Mediterranean Sea, Baltic Sea, Black Sea, Red Sea, the Gulfs area, Gulf of Aden, Antarctic area, North West European waters, Oman area of the Arabian Sea and Southern South African waters. Inside a special area, processed machinery space bilge water may still be discharged under the same conditions as outside, but the oil filtering equipment must have the 15 ppm alarm and automatic stopping device, whatever the ship’s size. In the Antarctic area, any discharge of oil or oily mixture from any ship is prohibited. In Arctic waters, oil discharges are also prohibited under the Polar Code.
Reference: MARPOL Annex I, Regulations 1.11, 15.3 and 15.4
Q4. Describe how a 15 ppm bilge separator works.
Bilge water from the bilge holding tank is fed by a low-shear pump (usually a positive displacement screw or piston pump) to the first stage, a gravity separator. Here the oil droplets rise because they are lighter than water, helped by coalescing plates and, on many units, heating. Separated oil collects at the top and is discharged to the waste oil or sludge tank, usually controlled automatically by an oil-level probe. The water then passes through a second stage, such as coalescing filter elements, absorbent filters or a membrane unit, to remove the fine droplets. The effluent is sampled continuously by the 15 ppm bilge alarm, which controls a three-way valve: below 15 ppm the water goes overboard, above 15 ppm it is sent back to the bilge tank.
Q5. Why are emulsions a problem for the separator, and how do you avoid them?
In an emulsion the oil is broken into droplets so fine that they do not rise by gravity, so they pass through the separator and give high ppm readings and early filter clogging. Emulsions are caused by high-shear pumps (centrifugal pumps), cleaning chemicals and detergents in the bilges, and violent mixing in the bilge wells. To avoid them, use the low-shear pump supplied with the separator, keep detergents and cleaning chemicals out of the bilges as far as possible, give the bilge holding tank time to settle, and drain off settled oil before processing. MARPOL also prohibits adding chemicals or other substances to get around the discharge conditions.
Reference: MARPOL Annex I, Regulation 15; MEPC.107(49)
Q6. What are the main requirements for a 15 ppm bilge alarm under MEPC.107(49)?
- It applies to equipment installed on or after 1 January 2005, which must be type-approved to MEPC.107(49).
- It must activate the alarm and the automatic stopping device when the effluent exceeds 15 ppm, and also if the alarm unit fails, is warming up or loses power.
- The display response time should not exceed 5 seconds, and the whole system should respond within 20 seconds.
- It must record the date, time, alarm status and operating status of the separator, and keep these records for at least 18 months.
- It must be arranged so that it cannot be tampered with, and the sample must be truly representative of the overboard effluent.
- Its accuracy must be checked by the manufacturer or a person authorised by the manufacturer, at the interval given in MEPC.107(49) as amended by MEPC.285(70) or the maker’s instructions, and the calibration certificate kept on board for checking at IOPP surveys.
Reference: Resolution MEPC.107(49), as amended by MEPC.285(70)
Q7. How do you start and run the oily water separator on watch?
- Get permission from the Chief Engineer as per company procedure, and confirm with the bridge that the ship is en route and not in a special area where your equipment is not allowed to discharge, or within any local no-discharge zone.
- Check the bilge holding tank level and let it settle; drain settled oil to the sludge or waste oil tank first.
- Fill the separator with clean water, check that the 15 ppm alarm has been flushed and zeroed as per the maker’s manual, and that the three-way valve works.
- Start the separator and watch the ppm reading, oil discharge, pressures and the overboard effluent.
- Stop it when the holding tank reaches its low level, flush with clean water, and make the Oil Record Book entry with start and stop times, positions and quantities.
Q8. The 15 ppm alarm keeps going off and the effluent recirculates. What could be wrong, and what do you do?
Common causes are: emulsified bilge water or chemicals in the bilges; too much oil in the feed, or the separator’s oil chamber not discharging; dirty or saturated coalescer or filter elements; too high a feed rate or a worn pump; low temperature where heating is fitted; and a dirty measuring cell or air in the sample line giving a false reading. Stop the separator, never bypass or adjust the alarm, and find the cause: drain oil from the holding tank, clean or change the filter elements, clean the measuring cell and check it as per the maker’s manual. If the fault cannot be fixed, keep the bilge water on board for discharge to a reception facility, record the failure in the Oil Record Book and inform the Chief Engineer and the company.
Reference: MARPOL Annex I, Regulation 17 (failures to be recorded)
Q9. What is recorded in the Oil Record Book Part I, and who signs it?
It records machinery space operations under letter codes, for example: C for collection, transfer and disposal of oil residues (sludge), including the weekly sludge tank inventory; D for non-automatic discharge overboard, transfer or disposal of bilge water; E for automatic discharge of bilge water; F for the condition of the oil filtering equipment, including failures and repairs; G for accidental or other exceptional discharges of oil; H for bunkering of fuel or bulk lube oil; and I for additional operational procedures and general remarks. Each operation is signed by the officer in charge, and each completed page is signed by the Master. Entries must be made without delay, and the book is kept on board for three years after the last entry. Reception facility receipts are kept with it.
Reference: MARPOL Annex I, Regulation 17; MEPC.1/Circ.736/Rev.2
Q10. What does Regulation 12 require for oil residue (sludge) tanks?
Ships of 400 GT and above must have sludge tanks of adequate capacity for the type of machinery and length of voyage. The tanks must have a designated pump able to take suction from them for disposal; no discharge connections to the bilge system, oily bilge water holding tank, tank top or oily water separator (drains with manually operated self-closing valves to the bilge holding tank or bilge well are allowed); no piping with a direct connection overboard other than the standard discharge connection; and be designed so they are easy to clean and discharge to reception facilities. Sludge and bilge piping may share a common line to the standard discharge connection only if sludge cannot be transferred to the bilge system.
Reference: MARPOL Annex I, Regulation 12 (as amended by MEPC.266(68))
Q11. How can sludge be disposed of legally?
Sludge may be discharged to a shore or barge reception facility through the standard discharge connection, or disposed of by an approved means listed in the Supplement to the IOPP Certificate, such as burning in an incinerator or in an auxiliary boiler suitable for burning sludge. Water may be drained or evaporated from the sludge tank, and the remaining quantity recorded. Every disposal is entered in the Oil Record Book under code C, and the receipt from the reception facility is kept with the book. Sludge must never be sent to the bilge system or the oily water separator.
Reference: MARPOL Annex I, Regulations 12 and 13; MEPC.1/Circ.736/Rev.2
Q12. A Port State Control officer comes to check MARPOL Annex I compliance in the engine room. What will they look at?
They will check the IOPP Certificate and its Supplement (required for oil tankers of 150 GT and above and other ships of 400 GT and above, valid for up to five years with annual and intermediate surveys), the SOPEP, and the Oil Record Book. They compare Oil Record Book entries with the 15 ppm alarm records, sludge and bilge tank soundings and reception facility receipts. They may ask an engineer to run the separator and test that the alarm and automatic stopping device work, including with clean water flushing and with the sample flow stopped. They look for signs of a bypass, such as flexible hoses, spool pieces, fresh paint or loose flange bolts on overboard lines, and they check that the crew knows how to operate the equipment. Any false entry or bypass (“magic pipe”) can lead to detention and criminal prosecution of the ship’s officers.
Reference: MARPOL Annex I, Regulations 6, 7, 11, 17 and 37
Quick self-test
Choose your answer, then tap “Show answer” to check.
1. The maximum oil content of machinery space effluent discharged overboard, without dilution, is: (a) 5 ppm (b) 15 ppm (c) 30 ppm (d) 100 ppm
Answer: (b) 15 ppm, under MARPOL Annex I, Regulation 15.
2. In which area is any discharge of oil or oily mixture from any ship prohibited? (a) Mediterranean Sea (b) Baltic Sea (c) Antarctic area (d) Gulf of Aden
Answer: (c) The Antarctic area (Regulation 15.4).
3. The 15 ppm bilge alarm must store its records for at least: (a) 3 months (b) 6 months (c) 12 months (d) 18 months
Answer: (d) 18 months, as per MEPC.107(49).
4. The Oil Record Book Part I must be kept on board for: (a) one year (b) two years (c) three years after the last entry (d) five years
Answer: (c) Three years after the last entry has been made.
5. The best type of pump to feed an oily water separator is: (a) high-speed centrifugal (b) low-shear positive displacement (c) ejector (d) any bilge pump
Answer: (b) A low-shear pump avoids breaking the oil into an emulsion.
Disclaimer: These questions and model answers are study aids written by CrewMirror, not official examination questions or answers. The answers are kept brief, as suited to an oral examination; a written examination may need more detailed explanations, so please refer to your course materials and the latest rules, regulations and documents of the relevant authorities. Always follow your equipment maker’s instructions and your company’s procedures, and check the current MARPOL, IMO and flag State requirements and the latest DGMA examination requirements before your exam. CrewMirror and its owners and operators will not be responsible for any loss or damage caused by the use of information published on CrewMirror pages and posts.
This article was prepared with the help of Internet Search and AI assistance tools.